pvlib.temperature.sapm_module#
- pvlib.temperature.sapm_module(poa_global, temp_air, wind_speed, a, b)[source]#
- Calculate module back surface temperature per the Sandia Array Performance Model. - See [1] for details on the Sandia Array Performance Model. - Parameters:
- Returns:
- numeric, values in degrees C. 
 - Notes - The model for module temperature \(T_{m}\) is given by Eq. 11 in [1]. (1)#\[T_{m} = E \times \exp (a + b \times WS) + T_{a}\]- Inputs to the model are plane-of-array irradiance \(E\) (W/m2) and ambient air temperature \(T_{a}\) (C). Model outputs are surface temperature at the back of the module \(T_{m}\) and cell temperature \(T_{C}\). Model parameters depend both on the module construction and its mounting. Parameter sets are provided in [1] for representative modules and mounting, and are coded for convenience in - TEMPERATURE_MODEL_PARAMETERS.- Module - Mounting - a - b - \(\Delta T [C]\) - glass/glass - open rack - -3.47 - -0.0594 - 3 - glass/glass - close mount - -2.98 - -0.0471 - 1 - glass/polymer - open rack - -3.56 - -0.075 - 3 - glass/polymer - insulated back - -2.81 - -0.0455 - 0 - Mounting cases can be described in terms of air flow across and around the rear-facing surface of the module: - “open rack” refers to mounting that allows relatively free air flow. This case is typical of ground-mounted systems on fixed racking or single axis trackers. 
- “close mount” refers to limited or restricted air flow. This case is typical of roof-mounted systems with some gap behind the module. 
- “insulated back” refers to systems with no air flow contacting the rear surface of the module. This case is typical of building-integrated PV systems, or systems laid flat on a ground surface. 
 - References - See also 