pvlib.pvsystem.dc_ohms_from_percent#
- pvlib.pvsystem.dc_ohms_from_percent(vmp_ref, imp_ref, dc_ohmic_percent, modules_per_string=1, strings=1)[source]#
- Calculate the equivalent resistance of the conductors from the percent ohmic loss of an array at reference conditions. - Parameters:
- vmp_ref (numeric) – Maximum power voltage of one module at reference conditions. [V] 
- imp_ref (numeric) – Maximum power current of one module at reference conditions. [A] 
- dc_ohmic_percent (numeric) – Array DC power loss as a percent of DC power loss at reference conditions. In percent, e.g. 1.5% loss is input as 1.5. 
- modules_per_string (int, default 1) – Number of series-connected modules per string in the array. 
- strings (int, default 1) – Number of parallel strings in the array. 
 
- Returns:
- Rw (numeric) – Equivalent resistance. [ohm] 
 - See also - Notes - Equivalent resistance is calculated as: \[R_w = \left(\frac{L_{stc}}{100}\right) \times \left(\frac{ V_{array}}{I_{array}}\right)\]- \(R_w\) is the equivalent resistance in ohms. \(V_{array}\) is the array voltage, equal to - vmp_reftimes- modules_per_string. \(I_{array}\) is the array current, equal to- imp_reftimes- strings. \(L_{stc}\) is the input DC loss percent at reference conditions.