pvlib.temperature.faiman#
- pvlib.temperature.faiman(poa_global, temp_air, wind_speed=1.0, u0=25.0, u1=6.84)[source]#
- Calculate cell or module temperature using the Faiman model. - The Faiman model uses an empirical heat loss factor model [1] and is adopted in the IEC 61853 standards [2] and [3]. - Usage of this model in the IEC 61853 standard does not distinguish between cell and module temperature. - Parameters:
- poa_global (numeric) – Total incident irradiance [W/m^2]. 
- temp_air (numeric) – Ambient dry bulb temperature [C]. 
- wind_speed (numeric, default 1.0) – Wind speed in m/s measured at the same height for which the wind loss factor was determined. The default value 1.0 m/s is the wind speed at module height used to determine NOCT. [m/s] 
- u0 (numeric, default 25.0) – Combined heat loss factor coefficient. The default value is one determined by Faiman for 7 silicon modules in the Negev desert on an open rack at 30.9° tilt. \(\left[\frac{\text{W}/{\text{m}^2}}{\text{C}}\right]\) 
- u1 (numeric, default 6.84) – Combined heat loss factor influenced by wind. The default value is one determined by Faiman for 7 silicon modules in the Negev desert on an open rack at 30.9° tilt. \(\left[ \frac{\text{W}/\text{m}^2}{\text{C}\ \left( \text{m/s} \right)} \right]\) 
 
- Returns:
- numeric, values in degrees Celsius 
 - Notes - All arguments may be scalars or vectors. If multiple arguments are vectors they must be the same length. - References - See also 
Examples using pvlib.temperature.faiman#
 
Simulating PV system DC output using the ADR module efficiency model
 
4.7 MW CdTe single-axis tracking (OEDI System 9068)
 
    
  
  
 
 