pvlib.pvsystem.Array#
- class pvlib.pvsystem.Array(mount, albedo=None, surface_type=None, module=None, module_type=None, module_parameters=None, temperature_model_parameters=None, modules_per_string=1, strings=1, array_losses_parameters=None, name=None)[source]#
- An Array is a set of modules at the same orientation. - Specifically, an array is defined by its mount, the module parameters, the number of parallel strings of modules and the number of modules on each string. - Parameters:
- mount (FixedMount, SingleAxisTrackerMount, or other) – Mounting for the array, either on fixed-tilt racking or horizontal single axis tracker. Mounting is used to determine module orientation. If not provided, a FixedMount with zero tilt is used. 
- albedo (float, optional) – Ground surface albedo. If not supplied, then - surface_typeis used to look up a value in- pvlib.albedo.SURFACE_ALBEDOS. If- surface_typeis also not supplied then a ground surface albedo of 0.25 is used.
- surface_type (string, optional) – The ground surface type. See - pvlib.albedo.SURFACE_ALBEDOSfor valid values.
- module (string, optional) – The model name of the modules. May be used to look up the module_parameters dictionary via some other method. 
- module_type (string, optional) – Describes the module’s construction. Valid strings are ‘glass_polymer’ and ‘glass_glass’. Used for cell and module temperature calculations. 
- module_parameters (dict or Series, optional) – Parameters for the module model, e.g., SAPM, CEC, or other. 
- temperature_model_parameters (dict or Series, optional) – Parameters for the module temperature model, e.g., SAPM, Pvsyst, or other. 
- modules_per_string (int, default 1) – Number of modules per string in the array. 
- strings (int, default 1) – Number of parallel strings in the array. 
- array_losses_parameters (dict or Series, optional) – Supported keys are ‘dc_ohmic_percent’. 
- name (str, optional) – Name of Array instance. 
 
 - Methods - __init__(mount[, albedo, surface_type, ...])- Calculates the equivalent resistance of the wires using - pvlib.pvsystem.dc_ohms_from_percent()- get_aoi(solar_zenith, solar_azimuth)- Get the angle of incidence on the array. - get_cell_temperature(poa_global, temp_air, ...)- Determine cell temperature using the method specified by - model.- get_iam(aoi[, iam_model])- Determine the incidence angle modifier using the method specified by - iam_model.- get_irradiance(solar_zenith, solar_azimuth, ...)- Get plane of array irradiance components. 
Examples using pvlib.pvsystem.Array#
 
4.7 MW CdTe single-axis tracking (OEDI System 9068)
 
    
  
  
 
 
 
 