pvlib.pvsystem.PVSystem.get_cell_temperature#
- PVSystem.get_cell_temperature(poa_global, temp_air, wind_speed, model, effective_irradiance=None)[source]#
- Determine cell temperature using the method specified by - model.- Parameters:
- poa_global (numeric or tuple of numeric) – Total incident irradiance in W/m^2. 
- temp_air (numeric or tuple of numeric) – Ambient dry bulb temperature in degrees C. 
- wind_speed (numeric or tuple of numeric) – Wind speed in m/s. 
- model (str) – Supported models include - 'sapm',- 'pvsyst',- 'faiman',- 'fuentes', and- 'noct_sam'
- effective_irradiance (numeric or tuple of numeric, optional) – The irradiance that is converted to photocurrent in W/m^2. Only used for some models. 
 
- Returns:
- numeric or tuple of numeric – Values in degrees C. 
 - See also - Notes - The temp_air and wind_speed parameters may be passed as tuples to provide different values for each Array in the system. If passed as a tuple the length must be the same as the number of Arrays. If not passed as a tuple then the same value is used for each Array. 