pvlib.pvsystem.FixedMount#
- class pvlib.pvsystem.FixedMount(surface_tilt: float = 0.0, surface_azimuth: float = 180.0, racking_model: str | None = None, module_height: float | None = None)[source]#
- Racking at fixed (static) orientation. - Parameters:
- surface_tilt (float, default 0) – Surface tilt angle. The tilt angle is defined as angle from horizontal (e.g. surface facing up = 0, surface facing horizon = 90) [degrees] 
- surface_azimuth (float, default 180) – Azimuth angle of the module surface. North=0, East=90, South=180, West=270. [degrees] 
- racking_model (str, optional) – Valid strings are - 'open_rack',- 'close_mount',- 'insulated_back',- 'freestanding',- 'insulated', and- 'semi_integrated'. Used to identify a parameter set for the SAPM or PVsyst cell temperature model. See- sapm_module()and- pvsyst_cell()for definitions.
- module_height (float, optional) – The height above ground of the center of the module [m]. Used for the Fuentes cell temperature model. 
 
 - Methods - __init__([surface_tilt, surface_azimuth, ...])- get_orientation(solar_zenith, solar_azimuth)- Determine module orientation. - Attributes - module_height- racking_model- surface_azimuth- surface_tilt
 
    
  
  
 
 